

Protective Louvers for Security-Critical Buildings
Force protection louvers provide protection at building openings where security and ventilation must work together. Ballistic-resistant and forced-entry louvers address different threats, with performance requirements defined by the project.
We offer louver solutions for security-critical buildings, with configurations selected according to the required protection level, opening design and operational needs for your facility.
Force ProtectionLouvers Solutions
Ballistic Resistant Louvers
Key Features Armour-steel profiles designed to resist projectile penetration Ventilation and airflow through the louver assembly Fixed, sliding and awning configurations Options selected according to the required ballistic protection level Applicable Standards NIJ 0108.01 Level IV EN 1522 FB7 EN 1063 BR7 NATO STANAG 4569 Level 5 The applicable standard and classification depend on the specific product, threat and tested configuration.
Forced-Entry Louvers
Forced-entry louvers are designed to resist attempts to gain access using manual and powered tools. The required resistance level depends on the anticipated threat and the security requirements of the building. Key Features Resistance to specified manual and powered tool attacks Configurations selected for the required security level Potential integration with other building protection measures Applicable Standards EN 1627 RC5 EN 1627 RC6 The applicable resistance class must be supported by test evidence for the selected system and configuration.
Applications
Openings Requiring Ballistic Protection
Ballistic-resistant louvers can be considered where a building opening requires protection against a defined projectile threat. Suitability depends on the required resistance, opening arrangement and proposed assembly.
Openings Requiring Intrusion Resistance
Forced-entry louvers address openings identified as potential unauthorised access routes. Selection should reflect the tools and attack conditions the system is required to resist.
Security and Ventilation Requirements
Where ventilation openings require additional protection, airflow and security criteria should be assessed together. Our louver options are designed to address protective requirements while maintaining ventilation, subject to the selected configuration and its performance characteristics.
Performance and Technical Considerations
Threat-Specific Performance
The specification should identify the required ballistic or forced-entry resistance and the applicable project standards. Supporting evidence must correspond to the proposed product configuration. Blast resistance is a separate requirement. It should only be included where suitable performance evidence supports the selected louver system.
Assembly and Installation
Louver configuration, opening dimensions and installation details form part of the protection specification. Assessment should consider how the assembly connects with the surrounding construction.
Blast-Resistant Options
Certain blast-resistant louver systems are specified for performance of up to 70 psi reflected pressure and 320 psi·ms reflected impulse. These figures apply only to configurations supported by relevant test evidence and should not be assumed to apply to all louver systems.
Airflow and Operation
For ventilation applications, establish airflow demand and assess the proposed product’s ventilation characteristics. Operating arrangements and maintenance access also need consideration during selection.
Sectors We Protect

Oil and Gas

Commercial and Industrail

Airports

Government & Defence

Data Centres

Ports and Logistics


Engineering, Integration and Delivery
Selecting a suitable louver requires coordination between security, structural and building-services requirements. Our team can review the project requirements with you, including:
- Opening dimensions and surrounding construction
- Required ballistic or forced-entry resistance
- Applicable standards and test documentation
- Ventilation and airflow requirements
- Installation constraints for new-build or retrofit projects
- Additional blast protection requirements, where applicable

Have any Questions
Frequently Asked Questions
No. Ballistic, forced-entry and blast resistance address different threats. Blast protection must be established separately for the selected louver system.
Some configurations may support combined protection. The required performance for each threat must be confirmed against the relevant test evidence.
Relevant standards may include NIJ 0108.01 Level IV, EN 1522 FB7, EN 1063 BR7 and NATO STANAG 4569 Level 5. The applicable classification depends on the product and tested configuration.
Airflow demand, free area and pressure drop are important considerations when selecting a louver for a ventilation opening.
Retrofit suitability depends on the existing opening, surrounding construction and installation requirements. It must be assessed for the specific building and selected system.

