Tested Performance
320 psi·ms blast impulse resistance
BMF withstands a blast impulse of 320 psi·ms.
155 mm artillery testing
The system has undergone testing involving direct hits from 155 mm artillery ammunition.
Full-scale blast testing
BMF has been tested for blast protection of concrete and masonry walls.
Applications

Internal and External Walls
BMF can protect internal, external and surrounding concrete or masonry walls. Its force-dispersing function helps reduce the risk of collapse and hazards from falling wall material.

Retrofit and Historical Buildings
BMF is suitable for retrofit applications, including historical buildings. It allows additional blast protection to be integrated with existing structures, with installation planned around the wall construction and architectural requirements.

Walls with Blast-Proof Windows
BMF can be deployed on walls containing blast-proof windows. Wall protection and window interfaces are coordinated within the wider blast protection design.

Oil Refinery Wall Protection
BMF can be used at oil refineries to protect walls against vapour cloud explosion hazards. The application is assessed against the relevant explosion scenario and building requirements.


Retrofit suitability
- Retrofit suitability: Applicable to existing structures and historical buildings.
- Flexible wall applications: Suitable for internal, external and surrounding walls.
- Protected window integration: Can be installed on walls incorporating blast-proof windows.
- Cost-effective protection: Offers a practical solution for upgrading wall blast resistance.
- Environmentally friendly material: Provides an environmentally friendly fabric option for blast mitigation.
- Porous construction: Helps prevent condensation and maintain ventilation.
- Paintable surface: Can be finished using commercially available paints.
- Fire-retardant fabric: Incorporates fire-retardant material.


Engineering & Delivery
We support the integration of BMF from initial assessment through installation and ongoing support:
- Threat assessment and system design.
- Engineering and specification support.
- Project management and stakeholder coordination.
- Supply, installation and commissioning.
- Training, post-installation support and maintenance.
Sectors We Protect

Oil and Gas

- Retrofit blast protection for existing buildings, including towers and hotels, where the threat assessment identifies a need for additional wall protection.
Commercial & Industrial

Airports

- Wall protection for embassies and government buildings, including internal, external and surrounding walls exposed to identified blast threats.
Government & Defence

Data Centres

- Concrete and masonry wall protection at refineries where vapour cloud explosions form part of the facility’s assessed hazards.
Ports and Logistics
Related Systems

Force Protection Doors & Windows
Integrate BMF wall protection with blast-resistant doors and windows where access points and glazed openings also require protection. We consider these interfaces as part of the wider protection design.

Cable Catch Systems
Cable Catch Systems can be considered where your wider blast mitigation design needs to address debris hazards alongside wall protection.
Frequently Asked Questions
Blast impulse measures pressure acting over time. The 320 psi·ms figure is a performance benchmark; project suitability also depends on blast pressure, duration, wall construction and the proposed installation.
The test demonstrates performance under the tested conditions. Different ammunition, impact conditions and wall configurations require assessment against the project’s specific threat profile.
Wall construction, dimensions, existing condition, drawings, openings and identified blast hazards provide the starting point. These details help establish suitability and engineering requirements.
Yes. BMF can be applied to walls containing blast-proof windows. The wall, window frame and surrounding connections need coordinated assessment to support the intended protection.
BMF can be painted using commercially available paints. The proposed paint and finish should be checked for compatibility with the selected system before application.